EclerPLEX Release Notes, v1.05r18, 14 Oct 2026

Changes from last version, v1.03r27, 01 Sep 2026:

--------------------------------------------------------

New features:

- Paging station template for Panels: A new Templates tab has been added, allowing a complete paging station to be created simply by selecting the priority input strip to be controlled. The template automatically generates all the required objects, grouped together and with their paths already assigned, making panel design significantly faster and easier.
- Step and repeat: New Step and repeat function for Panel objects (toolbar), allowing a grid to be created from a single object or group by specifying the number of columns, rows and desired gap.
- Inc/Dec button: New Inc/Dec button Panel object with a configurable step, which can target any matrix volume, source selector, analog port gain or VGPI.
- Page swipe setting: Page swipe can now be enabled or disabled from Panel properties, allowing a Panel to be configured so that pages can only be changed using Move to buttons.
- Move to pages in other Panels: Move to buttons can now target pages from other Panels. If the user does not have access to the destination Panel, the button has no effect.
- Auto clear zones: New Auto clear zones option in properties for Pagers button objects. When enabled, the selected paging zones are cleared after each use and must be selected again.
- Pager/Ducker project design: Improved UX when designing Pager/Ducker projects. The Edit/Deploy mode switch is now always available in the toolbar, and paging zone selection can be performed directly from the X-Point aux canvas in Edit mode.
- Matrix clear confirmation: A confirmation dialog is now shown before clearing the matrix, preventing it from being executed accidentally with a single click.
- Unavailable or not assigned port indicator: Strips with unavailable or unassigned ports are now flagged both in the matrix (index highlighted in orange) and in Properties. This makes it easy to detect at a glance, for example, when a previously connected BIO has been lost.
- Panel assignment from Users view: Panels can now be assigned to users directly from the Users view, in addition to assigning users from the Panels view.
- New GUEST devices: Added support for PAGE-X4 and PAGE-X10D.
- Monitor improvements: The Monitor can now be cleared from the general Monitor button in the app bar. When disabled, the last Monitor position remains visible.
- Notifications menu: Added Mark all as read and Delete all options.
- Preset loading in LOG: Preset loads are now recorded in the LOG.
- Preset creation and capture: Improved UX/UI when creating and capturing presets, making it clearer which presets have been created but do not yet contain any captured data.
- Multi-path preset buttons: Panel buttons targeting presets now support multiple paths, allowing several presets to be recalled at once.
- EclerPLEX button: A link to ecler.com/eclerplex has been added to the app bar.

--------------------------------------------------------

Resolved software/firmware issues:

- Keyboard shortcuts on macOS now correctly use Cmd instead of Ctrl.
- Resolved an issue on macOS where the Device aux canvas section moved every time the tab was changed.
- Multi-selection of matrix knobs using the arrow keys with Ctrl/Cmd pressed now works correctly.
- Resolved an issue where loading presets affecting matrix X-Points could leave matrix groups or source selectors in an incorrect state.
- Dynamic text objects targeting strip volume now work correctly.
- Fixed calendar events with a custom frequency not triggering correctly.
- Resolved a long delay when sending TCP/UDP Strings.
- Undo now works correctly when editing TCP/UDP String events, and Redo has been added.
- TCP/UDP Strings longer than 255 bytes are now saved correctly when the event is first created. The 20-line limit has been removed and a character counter has been added to the text field.
- Improved UX when grouping and ungrouping Panel objects.
- Long device names are now displayed correctly in the Discovery dialog.
- Several improvements to the simulator at epx.ecler.com. From this version onwards, session data is no longer lost if the session reboots due to an error.
- Minor DSP and firmware stability improvements.


###########################################################################################################


EclerPLEX Release Notes, v1.03r27, 01 Sep 2026

Changes from last version, v1.03r25, 27 Aug 2026:

--------------------------------------------------------

Resolved software/firmware issues:

- Resolved a data conversion issue affecting Panel LED objects that caused errors when importing a backup or updating from an older firmware version.


###########################################################################################################


EclerPLEX Release Notes, v1.03r25, 27 Aug 2026

Changes from last version, v1.03r23, 03 Aug 2026:

--------------------------------------------------------

New features:

- EclerPLEX Panels mobile app: First release of the EclerPLEX Panels app now available for both Android and iOS.

--------------------------------------------------------

Resolved software/firmware issues:

- Cross-project Probes are now correctly taken into account when protecting the outputs of destination projects while DSP changes are being applied in the source project.
- Resolved an issue where Panel Buttons did not interact correctly with GPOs from a PULSO. This now works correctly from both PULSO and EclerPLEX Panels app.


###########################################################################################################


EclerPLEX Release Notes, v1.03r23, 03 Aug 2026

Changes from last version, v1.03r21, 28 Jul 2026:

--------------------------------------------------------

Resolved software/firmware issues:

- Resolved an issue where audio inputs on hot-plugged BIOs did not respond until VIVO was rebooted.
- Fixed a false "Dante is not licensed" notification shown during startup on VIVOs with Dante.


###########################################################################################################


EclerPLEX Release Notes, v1.03r21, 28 Jul 2026
 
Changes from last version, v1.02r24, 12 Jun 2026:

--------------------------------------------------------
 
New features:

- New VIVO/BIO models support: The system now supports the entire range of VIVOs and BIOs, with a variable number of audio and control ports per module. 
- Port numbering: Default port labels and indexes have been updated to use a combined BIO index and port index for accurate addressing across all connected hardware.
- Internal ports have been moved to a dedicated tab for improved navigation and clarity.
- VIVO without Dante support: Added support for VIVO units without a Dante module, including correct handling of Dante LED indicators and error reporting for these configurations.
- Signal Detector: New Signal Detector DSP block that can be linked to a VGPI and used as an event trigger or to monitor signal present value using a panel LED.
- DSP chain editing: Improved paste and insert behavior for DSP blocks within a chain, including the ability to insert a copied block at the beginning of a chain.
- Resize using all handles: Panel objects can now be resized from all 4 sides and all 4 corners, providing full control over object dimensions.
- Button objects as event triggers: Button panel objects can now be configured to trigger events directly, expanding the range of event types accessible from panel controls.
- Panel VU meters can now target VU meters of individual audio ports directly, including inputs, outputs and internal ports.
- GPI values are now displayed in the path selector, making them easier to identify when configuring Events or Panels.

--------------------------------------------------------
 
Resolved software/firmware issues:

- Resolved a 1 dB gain offset that could occur between an input and an output in the DSP signal path.
- Cloud Sync datetime displayed on VIVO LCD now shows "---" when the device has not yet synchronized with EclerCLOUD, instead of showing an incorrect or empty value.
- GPI-triggered events were being executed regardless of their "On boot-up" flag value; this has now been corrected.
- Improved Source selector control events to prevent unexpected jumps between selected inputs when using a WPaVOL-SR as a trigger.
- Color picker dialog now displays HEX codes correctly and Copy/Paste functions work as expected.
- Resolved an issue where text input fields could unexpectedly lose focus, causing typed characters to appear in the wrong place.
- Scroll behavior in list views (Devices, Projects, Presets, Panels, Users) no longer produces erratic movement.
- Search fields in the path selector are now fully functional.
- PULSO page order now updates correctly as per client configuration.
- Panel objects with text now apply font size changes correctly when resizing with Shift.
- Fixed an issue where the minimum size of Panel objects was not updating correctly when modified via properties.
- Minor DSP and firmware stability improvements.


###########################################################################################################


EclerPLEX Release Notes, v1.02r24, 12 Jun 2026

Changes from last version, v1.02r20, 09 Jun 2026:

--------------------------------------------------------

Resolved software/firmware issues:

- Resolved an issue related to PEQ DSP blocks that could occasionally result in abnormal output levels.
- Fixed Reverse mode on Source selector control and Source selector volume events.
- Minor UI improvements to New event dialog.
- Corrected a bug that could cause presets not to load correctly or an unexpected reboot when loading a preset.
- Addressed inconsistencies when controlling Source selectors from a Panel dropdown.


###########################################################################################################


EclerPLEX Release Notes, v1.02r20, 09 Jun 2026

Changes from last version, v1.00r0, 31 Mar 2026:

Overview

This release brings significant improvements to event scheduling, panel controls, source selectors, clock synchronization, and overall system stability. Key highlights include enhanced daily event repetition handling, new DSP filter options, expanded panel object capabilities, and numerous bug fixes across firmware and web interface.


Device & System
- LCD health indicator - The front panel screen now displays a general health error indicator when system issues are detected. 
- Firmware update error handling - Unmanaged firmware update errors are now properly reported.

Network & Connectivity
- HTTPS display - The device host address now correctly shows HTTPS when applicable. 
- Network conflict detection - Added checking when NET1 and NET2 are configured on the same network range, with user notification. 
- PULSO connection fixes
        - Fixed PULSO not connecting to the correct IP when NET1 was disconnected. 
        - PULSO now correctly detects changes to the Workspace ID (e.g., after regeneration). 
        - Improved auto-login and pairing behavior for deleted guests. 
- Deep Dive stability - Resolved audio dropouts and high DSP usage that could occur when initiating Deep Dive remote access. 

Matrix & Source Selectors
- Ordered source selectors - Source selectors now support user-defined ordering, with a new reordering option in properties. 
- Source selectors - OutMix groups coexistence - Now you can combine them to replicate selector’s functionality across multiple outputs.
- Real-time updates - Fixed delayed updates in Groups and Source Selectors when changes were made from a second client.

DSP & Audio
- Noise gate on outputs - Noise Gate DSP filter is now also available on output strips.
- Digital input trim & polarity - Digital inputs now support trim adjustment; polarity handling has been improved. 
- Ducker hold time - Extended maximum ducker hold time to 60 seconds. 
- Clock synchronization - Reworked the clock sync algorithm for improved accuracy, especially when NTP is active. The system now adapts continuously to clock divergences. 
- CPU load threshold - Increased maximum allowed CPU load from 80% to 85%, reflecting performance improvements. 

Events
- Daily repetition fix - Resolved a bug preventing daily event repetitions from triggering correctly. The calendar monitor now advances properly after the current date. 
- Source selector support in events - Events can now trigger source selector actions using GPI/VGPI control. 
- Last action tracking - Refactored how events track and display the last executed action, ensuring accurate status across the interface. 
- GPI/VGPI improvements - Fixed polarity not being read correctly for VGPI triggers; properties canvas now displays accurate settings.

Panels
- Knob & Slider enhancements - Knobs and sliders can now control analog inputs gain and source selectors (selected element volume). 
- Button hold mode - Buttons now support a dedicated HOLD mode for momentary actions. 
- VU Meters - Added Pre and Post DSP options for VU meter signal monitoring. 
- Undo/Redo - Fixed some bugs related to undo and redo support. 
- Alignment & snapping - Improved alignment lines for rotated and multi-selected objects; optimized snap-to-object behavior. 
- Group handling - Fixed issues with group reordering, object duplication, pasting, and resizing. 
- Combo object - Added background color option to dropdown combo objects. 
- Text & font - Fixed attributes not updating in duplicated objects. 
- User menu - Corrected menu positioning, sizing, and presence for PULSO devices. 

Web Interface
- Project properties - Fixed issues where project properties did not display after deselecting a strip. 
- Dashboard updates - Dashboard cards now update reliably when changes occur on another client. 
- Log filtering - "Yesterday" is now the second date filter option for easier log review. 
- PEQ graph - X-axis now spans 10 Hz to 30 kHz; added Y-axis options. 
- List view - Fixed single-tap selection in list views. 
- Text controllers - Improved memory management and responsiveness for text input fields throughout the interface.